Behind the Power Outage: Unmasking a New Intrusion Vector in Enterprise Infrastructure Tools
Symantec, Wednesday, November 18th, 2026
Symantec describes an intrusion that abused CyberPower PowerPanel Business UPS software to run scripts as SYSTEM on a domain controller.
Symantec's Threat Intelligence and Research Team analyzed an attack in which CyberPower PowerPanel Business (PPB), software for managing UPS devices, was the execution channel on a Windows domain controller.
The attacker uploaded .cmd scripts to PPB's extcmd folder via its web console's file-upload endpoint on TCP port 3052, and the ppbed.exe service ran them as SYSTEM.
Through this channel the attacker downloaded tools with certutil, loaded a .NET assembly in memory with PowerShell, used ntdsutil and esentutl to copy the Active Directory database ntds.dit, and then launched an implant, upnpcont.exe, which side-loaded a malicious atl.dll.
Public advisories on PPB cover hard-coded credentials, a default administrator password and an upload path-traversal flaw.